| اسم المعدة | الاسم التجاري | رقم الموديل | بلد الصنع | رقم شهادة السلامة العالمية | نوع المختبر الفاحص |
|---|---|---|---|---|---|
| غطاء معوق للحريق - الغطاء المنتفخ | KNAUF |
Putty Pads KL/PF 60-01 fire resistance 60 minutes Putty Pads KL/PF 120-01 Fire resistance 120 minutes Knauf putty pads are blue sheets of intumescent, moldable putty designed for used inside metallic electrical sockete boxes for the purpose of fire protection. the putty pads are available in 170mm x 170mm and 230mm x 170mm sizes , both 3mm thick.standard test method : ASTM E 814-13 A |
WHI18-22825431 | INTERTEK TESTING SERVICE, USA | |
| أنظمة جدار | KNAUF |
12.5mm AQUAPANEL? Cement Board Indoor WallAssembly - EN 1364-1 - 1 HoursDesign No. KL/GBF 60-17Integrity - 68 minutes Insulation - 68 minutes Radiation - 68 minutes |
WHI25-22825444 | INTERTEK TESTING SERVICE, USA | |
| أنظمة جدار | KNAUF |
KNAUF - 15.9mm GW -TX 15.9mm GB- WRTX Mold board wall assembly -ASTM E119- 60 Minutes -Design Number KL/GBF 120-18.Fire Resistance Rating - 60 minutes |
WHI25-22825445 | INTERTEK TESTING SERVICE, USA | |
| أنظمة جدار | KNAUF |
1 hr. Fire Rated Non-loadbearing wall assemblyModel: Knauf 12.5mm RG-X Gypsum BoardsDesign Number: KL/GBF 60-14Minimum thickness of the wall - 100mmIntegrity: 60 minutesRadiation: 60 minutesInsulation: 60 minutes |
WHI24-22825438 | INTERTEK TESTING SERVICE, USA | |
| أنظمة جدار | KNAUF |
12.5 mm Aquapanel Cement Board Outdoor and 12.7 mm GW-TX Gypsum board wall assemblyThe asymmetrical, 3050 x 3050 mm (10 ft x 10 ft), non-load bearing wall was constructed of steel studs, gypsum board, insulation, and cement board.KL/GBF 120-12ASTM E119- 120 minutes |
WHI18-22825423 | INTERTEK TESTING SERVICE, USA | |
| أنظمة جدار | KNAUF |
12.5mm FM DFH1 12.5mm FR DFA 3000mm x 3000mm, non-load-bearing wall was constructed of galvanized steel track, and two layers of 12.5mm FM DFH1 & FR DF boards on each side of the framing members.Integrity - 120 minutesInsulation - 120 minutes |
WHI23-22825435 | INTERTEK TESTING SERVICE, USA | |
| أنظمة جدار | KNAUF |
TYPE X-Partition wall, Non Loadbearing wall AssemblyType X Gypsum board Design model Number KL-GBF 60-04 Design Model number KL-GBF 60-02 Fire resistance test 1 hr Head of wall width: 63.5 mmTotal thickness: 63.6 mmLength: unrestricted |
الإمارات العربية المتحدة | WHI15-22825401 | INTERTEK TESTING SERVICE, USA |
| أنظمة جدار | KNAUF |
Type X Gypsum Board-Non Combustible Floor/ceiling Assembly12.7 mm thick knauf GW-TX Gypsum boards Design Model Number : KL-GBF 60-03 ASTM E119- rating 60 minutes.Head of wall width: 63.5 mmTotal thickness: 63.6 mmLength: unrestricted |
الإمارات العربية المتحدة | WHI15-22825401 | INTERTEK TESTING SERVICE, USA |
| أنظمة جدار | KNAUF |
1 1/2 hr. Fire Rated Non-loadbearing wall assemblyModel: Knauf 12.5mm RG-X Gypsum BoardsDesign Number: KL/GBF 60-15Knauf Regular Gypsum X Boards (RG-X) (density >=592 kg/m?) on both sides of a framing system made of GI studs and tracks infilled with 50mm layer of glass mineral wool insulation (density-16 kg/m?). Minimum thickness of the wall - 100mm.Integrity : 63 minutes Insulation : 63 minutes Radiation : 63 minutes |
WHI24-22825439 | INTERTEK TESTING SERVICE, USA | |
| أنظمة جدار | KNAUF |
Fire rated Non Load Bearing Wall Assembly 60 minModel: Knauf 12.5mm RG gypsum boardsDesign number: KL/GBF 60-20Density >=592kg/m?Minimum thickness of the wall - 100mmIntegrity : 63 minutes Insulation : 63 minutes Radiation : 63 minutes |
الإمارات العربية المتحدة | WHI1622825415 | INTERTEK TESTING SERVICE, USA |
| أنظمة جدار | KNAUF |
1 1/2 hr. fire rated non loadbearing wall assemblyKNAUF 12.5 FR W112 SYSTEM Design number : KL-GBF 90-01 Dry wall partitions are made of 2 layers of 12.5mm knauf FR gypsum board on both sides of a framing system made of GI studs and tracks.Intergraty - 103 minutes Insulation 92 minutes |
الإمارات العربية المتحدة | WHI15 -22825413 | INTERTEK TESTING SERVICE, USA |
| أنظمة جدار | KNAUF |
KNAUF GW-TX, DH-H1 non-loadbearing wall AssemblyDesign model no: KL/GBF 120-02 Fire resistance test 2 (two) hoursHead of wall width: 63.5 mmTotal thickness: 63.6 mmLength: unrestricted |
الإمارات العربية المتحدة | WHI15-22825401 | INTERTEK TESTING SERVICE, USA |
| أنظمة جدار | KNAUF |
Partition Wall, Non Loadbearing wall AssemblyType X Gypsum board design model no KL/GBF 120-05: Fire rating 120 minutes design model no KL/GBF 120-06: Fire rating 120 minutesHead of wall width: 63.5 mmTotal thickness: 63.6 mmLength: unrestricted |
الإمارات العربية المتحدة | WHI15-22825401 | INTERTEK TESTING SERVICE, USA |
| أنظمة جدار | KNAUF |
Knauf GW-TX and DH-H1, Knauf head of wall jointDesign model no: KL/GBF 120-03 fire resistance test: 2 (two) hoursHead of wall width: 63.5 mmTotal thickness: 63.6 mmLength: unrestricted |
الإمارات العربية المتحدة | WHI15-22825401 | INTERTEK TESTING SERVICE, USA |
| أنظمة جدار | KNAUF |
KNAUFGW-TX, knauf Head of wall JointDesign model no: KL/GBF 60-01 fire resistance test: 1 (one) hourHead of wall width: 63.5 mmTotal thickness: 63.6 mmLength: unrestricted |
الإمارات العربية المتحدة | WHI15-22825401 | INTERTEK TESTING SERVICE, USA |
| أنظمة جدار | KNAUF |
1 hr. Fire Rated Non-Loadbearing wall assembly KNAUF 12.5RG W112 SYSTEM Design model no: KL/GBF 60-05 fire resistance ratingIntegrity: 80 minutesInsulation: 73 minutesModel: Knauf regular gypsum board (RG)Knauf mold and moistureResistant gypsum board (MMR) |
الإمارات العربية المتحدة | WH15 -22825412 | INTERTEK TESTING SERVICE, USA |
| أنظمة جدار | KNAUF |
2 Hrs. Fire Rated Non-load bearing wall assemblyKNAUF 15 FR W112 System Design model no: KL/GBF 120-07 fire resistance rating Integrity: 129 minutesInsulation: 122 minutes |
الإمارات العربية المتحدة | WHI15-22825414 | INTERTEK TESTING SERVICE, USA |
| أنظمة جدار | KNAUF |
12.5mm Aqua panel cement board outdoor ,insulation and 1 layer of 15.9mm GW -TX Type -X Gypsum BoardThe 18 ft high x 14 ft wide ISMA test wall was constructed by representative for Knauf LLC. The assembly consisted of metal studs, gypsum board interior cladding, insulation batts, a moisture barrier, and cementitious exterior sheathing.KL/GBF 30-02 |
WHI17-22825420 | INTERTEK TESTING SERVICE, USA | |
| أنظمة جدار | KNAUF |
12.5mm Aqua panel cement board indoor ,one layer of 12.7mm GW-TX behind Aqua panel, insulation and two layers of 12.7 mm GW-TX Type -X gypsum board model ASTME119- rating: 2 hoursDesign no: KL/GBF 120-11The asymmetrical, 3050 x 3050 mm (10 ft x 10 ft), non-load-bearing wall was constructed of steel studs, gypsum board, insulation, and cement board. |
WHI17-22825421 | INTERTEK TESTING SERVICE, USA | |
| أنظمة جدار | KNAUF |
12.5mm FM, RF or Pro HD Board Wall Assembly 1-2 HoursDesign model no: KL/GBF 120-09 fire resistance ratingIntegrity: 126 minutesInsulation: 120 minutesA 3000mm x 3000mm, non-load-bearing wall was constructed of galvanized steel studs, galvanized steel track, and two layers of 12.5 mm FM Boards on each side of the framing members.EN 1364-1(2015) |
الإمارات العربية المتحدة | WHI16-22825427 | INTERTEK TESTING SERVICE, USA |
| أنظمة جدار | KNAUF |
Knauf Fire Rated Access Panel modified BS 476 part 22Integrity rating 60 minutes The panel frame are made from 1.2 mm thick GI sheet metal, with the powder coating finish. Two layers of GW-TX type x 12.7 mm gypsum board are fitted within the access panel to improve the panel's fine resistance. |
WHI18-22825422 | INTERTEK TESTING SERVICE, USA | |
| أنظمة جدار | KNAUF |
KCUA-A116 Cinema Wall Model No: KL/GBF 180-03fire resistance 180 minsKnauf type x fire rated gypsum wall board (GW-TX) are 3600 x 1200 x 15.9mm (w x h x thick), used as non-load bearing triple layered gypsum board partition wall.The 3 hours system has been tested in accordance with ASTM E119.The system is constructed of Triple layers of 15.9 mm thick Knauf type x fire rated gypsum wall board (GW-TX), mounted on both exposed & unexposed face of the framing system.ASTM E119(2014) & ASTM E2226-12, NFPA 251, UL 263 |
WHI15-22825411 | INTERTEK TESTING SERVICE, USA | |
| أنظمة جدار | KNAUF |
15mm FM, FR, or Pro HD Wall Lining - 2 hours - En 1364-1Design Model Number KL/GBF 120-13Integrity - 125 minutes Insulation - 57 minutes Knauf fire & moisture resistant gypsum board (FM)- 1200 x 2400 x 15 mm thickKnauf fire resistant gypsum board (FR)- 1200 x 2400 x 15 mm thickKnauf pro HD- 1200 x 2400 x 15 mm thickKnauf pro Acoustik- 1200 x 2400 x 15 mm thickMaximum Height - 4mMaximum Width - Infinite |
WHI21-22825430 | INTERTEK TESTING SERVICE, USA | |
| أنظمة جدار | KNAUF |
Knauf steel Protekt Board systemKL/BI 120-1 fire resistance 120 minutesStructural steel beams are protected with Two or three layers of 12.5mm or 15mm thick FR boards with box-type protection on the bottom and sides of the beams using a clip and channel system. |
WHI22-22825433 | INTERTEK TESTING SERVICE, USA | |
| أنظمة جدار | KNAUF |
Knauf GW-TX & DH-H1Model No: KL/GBF 120-02Fire resistance 120minsHead of wall joint constructed - (4) 2-1/2"wide pieces - 15.9 mm thickHead of wall width: 63.5 mmTotal thickness: 63.6 mmLength: unrestricted |
WHI15-22825401 | INTERTEK TESTING SERVICE, USA | |
| أنظمة جدار | KNAUF | AQUAPANEL Cement Board Indoor - 3 hours -ASTM E2307 Mode No: KL/BPF 180-1Fire resistance 3 hoursDensity: 1050 kg/m?Thickness: 12.5mm | WHI21-22825432 | INTERTEK TESTING SERVICE, USA | |
| أنظمة جدار | KNAUF |
15mm FM,FM, Pro HD Board Shaft wall AssemblyA 3000mm x 3000mm, non-load bearing asymmetrical wall was constructed of galvanized steel studs, galvanized steel track, 2 layers of 15 mm FM Boards, and a single layer of 25mm core board.Fire rating - FM, FR, pro HD and pro acoustik board exposed:Integrity - 120 minutesInsulation - 73 minutesFire ratings - core board exposedIntegrity - 138 minutesInsulation - 135 minutes |
الإمارات العربية المتحدة | WHI16 22825428 | INTERTEK TESTING SERVICE, USA |
| أنظمة جدار | KNAUF |
Non- Load Bearing Floor/Ceiling Assembly Certified product: 60 minutes fire rated floor/ceiling assemblyModel: 12.7mm thick, Knauf GW-TX gypsum boardsdensity -600 kg/m?KL/GBF 60-03ASTM E119-12a |
الإمارات العربية المتحدة | WHI16 22825417 | INTERTEK TESTING SERVICE, USA |
| أنظمة جدار | KNAUF |
Non load bearing Floor/Ceiling Assembly 120 minModel No KL/GBF120-0815.9mm thick, knauf GW-TX gypsum boardsThe base layer was secured using Knauf TN 3.5 x 25 self-drilling screws spaced 8" (203mm) o.c.density -600 kg/m?ASTM E119-12a |
الإمارات العربية المتحدة | WHI 1622825418 | INTERTEK TESTING SERVICE, USA |
| أنظمة جدار | KNAUF |
Fire Rated Non Load Bearing Wall Assembly 60 MinModel: Knauf 15mm FM Gypsum Boards Non-Load Bearing Wall Assembly made of 1 layer of 15mm Knauf fire & Moisture resistant (FM) gypsum boardsDensity>= 584 kg/ m? on both sides of a framework made of GI studs and tracks infilled with 50mm layer of glass mineral wool insulation (density-16 kg/m?). Minimum thickness of the wall-80mmKL/GBF 60-10Integrity - 60 minutes heat Radiation - 60 minutes Insulation - 60 minutes |
الإمارات العربية المتحدة | WHI1622825416 | INTERTEK TESTING SERVICE, USA |
| أنظمة جدار | KNAUF |
12.5mm Regular Plus AA 3000mm x 3000mm, non-load-bearing wall was constructed of galvanized steel studs, galvanized steel track, and two layers of 12.5mm Regular Plus A boards on each side of the framing members.Fire resistance rating :Integrity - 60 minutes Insulation - 60 minutes |
WHI23-22825434 | INTERTEK TESTING SERVICE, USA | |
| أنظمة جدار | KNAUF | 15.9mm GW-TX Board Wall Assembly - ASTME119 - 120 minutes Design No. KL/GBF 120-17 Fire resistance rating - 120 minutes | WHI25-22825442 | INTERTEK TESTING SERVICE, USA | |
| أنظمة جدار | KNAUF |
Knauf - 12.7mm GB-WRTX, 12.7mm thick GW-TX,12.7mm GW-TX Impact & 12.7mm thick GB-WRTX Mold Board Wall Assembly - ASTM E119 - 120 minutesDesign No. KL/GBF 120-18Fire Resistance -120 minutes |
WHI25-22825446 | INTERTEK TESTING SERVICE, USA | |
| أنظمة جدار | KNAUF |
15mm FR Board Wall Assembly EN 1364-1 - 60 mintues Design No. KL/GBF 60-19Integrity - 91 minutes Insulation - 61 minutes Radiation - 91 minutes |
WHI25-22825443 | INTERTEK TESTING SERVICE, USA | |
| أنظمة جدار | KNAUF |
Knauf Fire rated access panel are intended for installation in horizontal floor/ceilling assemblies. the panel and frame are made from 1.2mmthick GI sheet metal,with a powder coating finish. Two layers of GW-TX-Type X 12.7 mm gypsum board are fitted within the access panel to improve the panels fire resistance.Integrity - 60 minutes |
WHI25-22825448 | INTERTEK TESTING SERVICE, USA | |
| أنظمة جدار | KNAUF |
Knauf -15mm FR Board wall lining EN 1364-1 120 min - Design Number : KL/GBF 120-19A 3000mm x 3000mm non- loadbearing wall was constructed of galvanized steel tracks and double layered knauf 15mm thick Fire resistant (FR) boards on the exposed face of the framing members.Integrity - 139 minutes Insulation - 57 minutes Radiation - 139 minutes |
WHI25-22825447 | INTERTEK TESTING SERVICE, USA | |
| أنظمة جدار | KNAUF |
Knauf -12.5mm FR Board Wall Assembly En-13641-2Hours-Design No KL/GBF120-16Integrity - 143 minutes Insulation - 141 minutes Radiation - 143 minutes |
WHI25-22825441 | INTERTEK TESTING SERVICE, USA | |
| أنظمة جدار | KNAUF | Knauf -12.7 mm GW -R Board Wall assembly -ASTM E119-60 minutes Design number - KL/GBF60-16Fire Resistance - 60 minutes | WHI25-22825440 | INTERTEK TESTING SERVICE, USA |