| اسم المعدة | الاسم التجاري | رقم الموديل | بلد الصنع | مصنع | رقم قيد الوكالة | تاريخ انتهاء قيد الوكالة |
|---|---|---|---|---|---|---|
| مثبط - دمج (دخان / حريق) مثبط | KAD AIR CONDITIONING | K-MFD-20.K-MSD-20.K-MSFD-20 | الإمارات العربية المتحدة | كيه .ايه .دي للتكيف | 3968 | |
| مثبط - دمج (دخان / حريق) مثبط | KAD AIR CONDITONING | Model :DFRD -800,DFRD-1200,DFRD-1600,DFRD-2000,DFRD-3000, Rating Insulation Type-A-30MIN AND TYPE-B-30MIN | الإمارات العربية المتحدة | كيه ايه دي للتكييف | 3968 | |
| مثبط - دمج (دخان / حريق) مثبط | KAD AIR CONDITINING |
k-fd-15-A-B-18K-FD-15-A-B-30K-FD-15-B-36FIRE DAMPERS FOR USE IN DYNAMIC SYSTEMS K-MFD-20SMOKE DAMPERS K-MSD-20 COMBINSTION FIRE SND SMOKE DAMPERS K-MSFD-20SEE ADDITIONAL DETAIL DETAILS PAGE -S |
الإمارات العربية المتحدة | كيه اي دي للتكييف | 3968 | |
| القنوات مقاوم للحريق | KAD AIR CONDITINING |
passed criteria according to the standard BS 476-24STABILITY:stability criterion was maintained throughout the 120 minutes of test durationINTEGRITY:The integrity criterion was maintained throughout the 120 minutes of test durationINSULATION:0 MIN |
الإمارات العربية المتحدة | KAD AIRCONDITIONING | 3968 | |
| القنوات مقاوم للحريق | FIRE RATED DUCT |
KNFRD-A/STABILITY:Stability criterion was maintained throughout the 120 minutes of test duration.SMOKE EXTRACTION:Smoke extraction criterion was maintained throughout the 120 minutes of test duration.INTEGRITY:The integrity criterion was maintained throughout the 120 minutes of test durationINSULATION:0 MIN |
الإمارات العربية المتحدة | KAD AIRCONDITIONING | 2050774 | |
| القنوات مقاوم للحريق | KAD AIR CONDITINING | KADS NONCOATED FIRE RATED DUCTWORK Type A | الإمارات العربية المتحدة | كيه اي دي للتكييف | 3968 | |
| القنوات مقاوم للحريق | KAD AIR CONDITINING |
KADs NONCOATED FIRE RATED DUCTWORKPassed criterion according to the standard BS 476-24:STABILITY:Stability criterion was mainted throughout the 128 minutes of test durationINTEGRITY:the integrity criterion was maintained throughout the 128 minutes of test durationINSULATION:0 MIN |
الإمارات العربية المتحدة | KAD AIRCONDITIONING | 3968 | |
| القنوات مقاوم للحريق | KAD AIR CONDITINING |
DELTA FIRE RATED DUCT WORK SYSTEMPassed criterion according to the standard BS 476-24:STABILITY:Stability criterion was maintained throughout the 122 minutes of test duration in duct A,and 157 minutes of test duration in duct BINTEGRITY:the integrity criterion was maintained throughout the 122 minutes of test duration in duct A,and 157 minutes of test duration in duct in BINSULATION:Thermal insulation criterion failed at minute 32 in Duct A, and at minute 5 induct B |
الإمارات العربية المتحدة | KAD AIRCONDITIONING | 3968 | |
| القنوات مقاوم للحريق | KAD AIR CONDITINING |
EFD-FIRE TYPE Bpassed criteria according to the standard BS 476-24STABILITY:stability criterion was maintained throughout the 120 minutes of test durationINTEGRITY:The integrity criterion was maintained throughout the 120 minutes of test durationINSULATION:0 MIN |
الإمارات العربية المتحدة | KAD AIRCONDITIONING | 3968 | |
| القنوات مقاوم للحريق | KAD AIR CONDITINING |
KADs NONCOATED passed criteria according to the standard BS 476-24STABILITY:stability criterion was maintained throughout the 247 minutes of test durationINTEGRITY:The integrity criterion was maintained throughout the 247 minutes of test durationSmoke Extraction:smoke extraction criterion was maintained throughout the 247 minutes of test durationFIRE RATED DUCTINSULATION:0 MIN |
الإمارات العربية المتحدة | KAD AIRCONDITIONING | 3968 | |
| مثبط - مثبط الدخان | KAD AIRCONDITIONING-MSD-20 | Model : K-MSD-20 Mounting Position: Vertical Class 1 1/2 Hours Leakage Class: II-250 FRAME THICKNESS-1.50MM | الإمارات العربية المتحدة | KAD AIRCONDITIONING | 3968 | |
| مثبط - مثبط الحريق | KAD AIR CONDITIONING- FIRE DAMPER&MFD-20 |
KAD AIR CONDITIONING- FIRE DAMPER&MFD-20Dampers For Fire Barrier Applications FIRE DAMPERS&MFD-20 Fire Dampers for Use in Static Systems:- Model: K-FD-15-A/B-18,K-FD-15-A/B-30,K-FD-15-A/B-36,K-FD-11,K-FD-12 Mounting Position: Vertical Class 1 1/2 Hours FRAME THICKNESS-1.20MM Fire Dampers for Use in Dynamic Systems:- Model K-MFD-20 Mounting Position: Vertical Class: 1 1/2 Hours Leakage Class: II-250 FRAME THICKNESS-1.50MM |
الإمارات العربية المتحدة | KAD AIRCONDITIOING | 3968 | |
| مثبط - دمج (دخان / حريق) مثبط | KAD AIRCONDITIONING-MSFD-20 |
COMBINATION FIRE AND SMOKE DAMPERS(FIRE LEAKAGE-RATED DAMPERS) Model: K-MSFD-20 Mounting Position: Vertical Class 1 1/2 Hours Leakage Class : II-250 FRAME THICKNESS-1.50MM |
الإمارات العربية المتحدة | KAD AIRCONDITIONING | 3968 | |
| القنوات مقاوم للحريق | Fire Rated Ventilation Duct, Smoke Duct & Kitchen Duct |
INSULATED FIRE RATED DUCTWORK TYPES A & B SYSTEM MODEL KIFRD FIRE Rated Ductwork:System Details: insulated fire-rated ductworkFire Rated Ventilation Duct (Stability, Integrity, and Insulation):120 minutes.Fire Rated Smoke Outlet Duct (Stability, Integrity, and Insulation):120 minutes.Fire Rated Kitchen Duct (Stability, Integrity, and Insulation):120 minutes.Orientation: vertical and horizontal.Material: galvanized steel sheet material or mild steel or stainless steel.Shape: rectangular and circular ductwork.Sizes: Maximum 3000 mm for the longer side of rectangular ductwork anda maximum diameter of 1250 mm for circular ductwork, as per theconstruction tables highlighted in Certificate Number ESL-24-11705 Issue 02.Thickness: as per construction tables highlighted in certificate number ESL-24-11705 Issue 02.Ancillary Items: not applicabl |
الإمارات العربية المتحدة | KAD AIR CONDITIONING L.L.C | 3968 | |
| القنوات مقاوم للحريق | KAD's KITCHEN DUCT TYPE A , TYPE B , KITCHEN EXHAUST |
BS 476 Part 24 defines two types of fire tests : Type A and Type B. Type A tests simulate fire originating outside the duct while Type B simulates fire originating inside the duct . Both tests assess the duct's ability to resist fire for a specified time, ensuring stability, integrity, and insulation( usage Kitchen Exhaust Duct )Fire Rated Kitchen Duct (Stability, Integrity, and Insulation) 120 Min, Orientation Vertical and Horizontal, Material, Mild Steel thickness 1.5 mm, Stainless Steel thickness 1.2 mm. Shape: Rectangular, Circular Ductwork as per the construction table highlighted in certificate Number ESL-24-11705 issue 02 |
الإمارات العربية المتحدة | KAD AIR CONDITIONING L.L.C | 3968 | |
| مثبط - مثبط الدخان | Smoke Damper K-MSD-20 | Model : K-MSD-20 Mounting Position: Vertical Fire Resistance Classification: 90 Min Leakage Class: II-250 FRAME THICKNESS-1.50MM | الإمارات العربية المتحدة | EH Price Gulf | 30524 | |
| مثبط - مثبط الدخان | SMOKE DAMPERS: Model SSD-3V-201 & SSD-3V-202 |
Classification for model SSD-3V-201: Leakage Classification: 1-350 Damper Mounting Position: Vertical and Horizontal Airflow and Pressure Closure Rating: 10.2 m/s and 1.0 KPa Damper Size:o Single Section Width (in): 8- 36 (min-max)o Single Section Height (in): 6- 48 (min-max)o Multiple Section (in): 144 x 96 (W x H)4. Classification for model SSD-3V-202: Leakage Classification: 11-350 Damper Mounting Position: Vertical and Horizontal Airflow and Pressure Closure Rating: 10.2 m/s and 1.0 KPa Damper Size:o Single Section Width (in): 8- 36 (min-max)o Single Section Height (in): 8- 48 (min-max)o Multiple Section (in): 144 x 96 (W x H) Classification for model SSD-3V-202 Leakage Classification: 11-350 Damper Mounting Position: Vertical and Horizontal Airflow and Pressure Closure Rating: 10.2 m/s and 1.0 KPa Damper Size:o Single Section Width (in): 8- 36 (min-max)o Single Section Height (in): 8- 48 (min-max)o Multiple Section (in): 144 x 96 (W x H) |
الإمارات العربية المتحدة | EH Price Gulf | 30524 | |
| مثبط - مثبط الدخان | Smoke Damper Model SSD-RD |
The SSD-RD-201 series Smoke Dampers have been designed and tested to exceed all U.L., U.L.C. and N.F.P.A. requirements for smoke dampers. These U.L. leakage rated dampers are intended for use in engineered smoke control systems to provide extremely tight shut off. U.L. 555S and U.L.C. S112.1 listed and labelled as Leakage Class I rated Smoke Damper with airflow in both directions. Class I provides for a maximum leakage of 8 cfm per sq. ft. at 4 inch static pressure. As we are constantly expanding our U.L./ U.L.C. listings, we suggest you contact the factory for further information. The SSD-RD-201 exceeds N.F.P.A. 90A & 92 smoke damper requirements and is recommended for applications that call for tight sealing requirements. The SSD-RD-201 provides excellent control of smoke movement or containment as the smoke management system demands. The SSD-RD-201 may be equipped with factory installed electric or pneumatic operators |
الإمارات العربية المتحدة | EH Price Gulf | 30524 | |
| مثبط - مثبط الدخان | Smoke Damper Model SSD-AF-201 & SSD-AF-202 |
. Classification for model SSD-AF-201 Leakage Classification: 1-250 Damper Mounting Position: Vertical and Horizontal Airflow and Pressure Closure Rating: 10.2 m/s and 1.0 KPa Damper Size:o Single Section Width (in): 8- 36 (min-max)o Single Section Height (in): 8- 48 (min-max)o Multiple Section (in): 144 x 96 (W x H)Classification for model SSD-AF-202 Leakage Classification: 11-350 Damper Mounting Position: Vertical and Horizontal Airflow and Pressure Closure Rating: 10.2 m/s and 1.0 KPa Damper Size:o Single Section Width (in): 6- 36 (min-max)o Single Section Height (in): 6- 48 (min-max)o Multiple Section (in): 144 x 96 (W x H) |
الإمارات العربية المتحدة | EH Price Gulf | 30524 | |
| مثبط - مثبط الحريق | Fire Damper Model FD-MB-AF |
Classification for model FD-MB-AF Fire Resistance Classification: 90 Min Damper Mounting Position: Vertical Damper Size: o Single Section (in): 36 x 48 (W x H) o Multiple Section (in): 108 x 96 (W x H) 5. Classification for model FD-MB-AF: Fire Resistance Classification: 90 Min Damper Mounting Position: Horizontal Damper Size: o Single Section (in): 36 x 48 (W x H) o Multiple Section (in): N/A 6. Classification for model FD-MB-AF: Hourly Classification: 3 Hrs. Damper Mounting Position: Vertical Damper Size: o Single Section (in): 36 x 48 (W x H) o Multiple Section (in): 72 x 48 (W x H) 7. Classification for model FD-MB-AF: Fire Resistance Classification: 180 Min Damper Mounting Position: Horizontal Damper Size: o Single Section (in): 36 x 48 (W x H) o Multiple Section (in): N/A |
الإمارات العربية المتحدة | EH Price Gulf | 30524 | |
| مثبط - مثبط الحريق | Fire Damper Model FD, FD-N, SL and FD-OW. FDD and FDD-SL, with or without suffix A, B or C, and Model FDD-OW |
Fire Damper for Use in Static System:1. Classification for model FD & FD-SL:Fire Resistance Classification: 90 Min .Damper Mounting Position: VerticalDamper Size:o Single Section (in): 60 x 60 (W x H)o Multiple Section (in): 120 x 120 (W x H)2. Classification for model FD & FD-SL:Fire Resistance Classification: 90 Min.Damper Mounting Position: HorizontalDamper Size:o Single Section (in): 48 x 48 (W x H)o Multiple Section (in): 96 x 48 (W x H)3. Classification for model FD & FD-SL:Fire Resistance Classification: 90 Min.Damper Mounting Position: HorizontalDamper Size:o Single Section (in): 40 x 40 (W x H)o Multiple Section (in): 120 x 40 (W x H)4. Classification for model FD & FD-SL:Hourly Classification: 3 Hrs.Damper Mounting Position: VerticalDamper Size:o Single Section (in): 48 x 48 (W x H)o Multiple Section (in): 80 x 40 (W x H)5. Classification for model FD & FD-SL:Fire Resistance Classification: 180 MinDamper Mounting Position: HorizontalDamper Size:o Single Section (in): 40 x 40 (W x H)o Multiple Section (in): 80 x 40 (W x H)6. Classification for model FD-OW:Fire Resistance Classification: 90 Min.Damper Mounting Position: Vertical & HorizontalDamper Size:o Single Section (in): 36 x 48 (W x H)o Multiple Section (in): N/AFire Dampers for Use in Dynamic Systems:1. Classification for model FDD, FDD-SL, & FDD-OW:Fire Resistance Classification: 90 Min. and 180 Min.Damper Mounting Position: VerticalShape: RectangularAirflow and Pressure Closure Rating: 10.2 m/s and 1.0 KPaDamper Size:o Maximum Single Section (in): 36 x 36 (W x H)o Multiple Section (in): 72 x 36 (W x H)2. Classification for model FDD, FDD-SL, & FDD-OW:Fire Resistance Classification: 90 Min. and 180 Min.Damper Mounting Position: VerticalShape: RectangularAirflow and Pressure Closure Rating: 10.2 m/s and 1.0 KPaDamper Size:o Maximum Single Section (in): 36 x 36 (W x H)o Multiple Section (in): 36 x 72 (W x H)3. Classification for model FDD, FDD-SL, & FDD-OW:Fire Resistance Classification: 90 Min. and 180 Min.Damper Mounting Position: HorizontalShape: RectangularAirflow and Pressure Closure Rating: 10.2 m/s and 1.0 KPaDamper Size:o Maximum Single Section (in): 18 x 18 (W x H)o Multiple Section (in): 36 x 36 (W x H) |
الإمارات العربية المتحدة | EH Price Gulf | 40861 | |
| مثبط - مثبط الحريق | FIRE DAMPER K-FD-15 & K-MFD-20 |
- FIRE DAMPER&MFD-20 Dampers For Fire Barrier Applications FIRE DAMPERS&MFD-20 Fire Dampers for Use in Static Systems:- Model: K-FD-15-A/B-18,K-FD-15-A/B-30,K-FD-15-A/B-36,K-FD-11,K-FD-12 Mounting Position: Vertical Fire Resistance Classification 90 Min FRAME THICKNESS-1.20MM Fire Dampers for Use in Dynamic Systems:- Model K-MFD-20 Mounting Position: Vertical Fire Resistance Classification 90 Min Leakage Class: II-250 FRAME THICKNESS-1.50MM |
الإمارات العربية المتحدة | EH Price Gulf | 30524 | |
| مثبط - مثبط الحريق | Fire Damper Model FD-MB-3V |
FIRE DAMPER FOR USE IN STATIC SYSTEM: Classification for model FD-MB-3V:Fire Resistance Classification: 90 Min. Damper Mounting Position: Vertical Damper Size:o Single Section (in): 36 x 48 (W x H)o Multiple Section (in): 108 x 96 (W x H)Classification for model FD-MB-3V:Fire Resistance Classification: 90 Min. Damper Mounting Position: Horizontal Damper Size:o Single Section (in): 36 x 48 (W x H)o Multiple Section (in): 72 x 48 (W x H) Classification for model FD-MB-3V:Fire Resistance Classification: 180 Min. Damper Mounting Position: Vertical & Horizontal Damper Size:o Single Section (in): 36 x 48 (W x H)o Multiple Section (in): 72 x 48 (W x H) Classification for model FD-MB-AF:Fire Resistance Classification: 90 Min. Damper Mounting Position: Vertical Damper Size:o Single Section (in): 36 x 48 (W x H)o Multiple Section (in): 108 x 96 (W x H) Classification for model FD-MB-AF:Fire Resistance Classification: 90 Min. Damper Mounting Position: Horizontal Damper Size:o Single Section (in): 36 x 48 (W x H)o Multiple Section (in): N/A Classification for model FD-MB-AF:Fire Resistance Classification: 180 Min. Damper Mounting Position: Vertical Damper Size:o Single Section (in): 36 x 48 (W x H)o Multiple Section (in): 72 x 48 (W x H) Classification for model FD-MB-AF:Fire Resistance Classification: 180 Min. Damper Mounting Position: Horizontal Damper Size:o Single Section (in): 36 x 48 (W x H)o Multiple Section (in): N/A |
الإمارات العربية المتحدة | EH Price Gulf | 30524 | |
| مثبط - مثبط الحريق | Fire Damper Model FDD-RD |
Classification for model FDD-RD:Fire Resistance Classification: 90 Min. Damper Mounting Position: Vertical & Horizontal Shape: circular Airflow and Pressure Closure Rating: 10.2 m/s and 1.0 KPa Damper Size:o Maximum Single Diameter (in): 24o Multiple Section (in): N/A |
الإمارات العربية المتحدة | EH Price Gulf | 30524 | |
| مثبط - مثبط الحريق | Fire Damper FDD-MB-AF |
Classification for model FDD-MB-AF: Fire Resistance Classification: 90 Min . Damper Mounting Position: Vertical Shape: Rectangular Airflow and Pressure Closure Rating: 10.2 m/s and 1.0 KPa Damper Size: o Maximum Single Section (in): 36 x 48 (W x H) o Multiple Section (in): 72 x 48 (W x H) 7. Classification for model FDD-MB-AF: Fire Resistance Classification: 90 Min . Damper Mounting Position: Horizontal Shape: Rectangular Airflow and Pressure Closure Rating: 10.2 m/s and 1.0 KPa Damper Size: o Maximum Single Section (in): 36 x 48 (W x H) o Multiple Section (in): N/A 8. Classification for model FDD-MB-AF: Fire Resistance Classification: 180 Min. Damper Mounting Position: Vertical & Horizontal Shape: Rectangular Airflow and Pressure Closure Rating: 10.2 m/s and 1.0 KPa Damper Size: o Maximum Single Section (in): 36 x 48 (W x H) o Multiple Section (in): 72 x 48 (W x H) |
الإمارات العربية المتحدة | EH Price Gulf | 30524 | |
| مثبط - مثبط الحريق | Fire Damper Model FDD-MB-3V |
Classification for model FDD-MB-3V: Fire Resistance Classification: 90 min . Damper Mounting Position: Vertical Shape: Rectangular Airflow and Pressure Closure Rating: 10.2 m/s and 1.0 KPa Damper Size: o Maximum Single Section (in): 36 x 48 (W x H) o Multiple Section (in): 72 x 48 (W x H) 2. Classification for model FDD-MB-3V: Fire Resistance Classification: 90 min. Damper Mounting Position: Horizontal Shape: Rectangular ? Airflow and Pressure Closure Rating: 10.2 m/s and 1.0 KPa ? Damper Size: o Maximum Single Section (in): 36 x 48 (W x H) o Multiple Section (in): 72 x 48 (W x H) 3. Classification for model FDD-MB-3V: Fire Resistance Classification: 180 Min. ? Damper Mounting Position: Vertical & Horizontal ? Shape: Rectangular ? Airflow and Pressure Closure Rating: 10.2 m/s and 1.0 KPa ? Damper Size: o Maximum Single Section (in): 36 x 48 (W x H) o Multiple Section (in): 72 x 48 (W x H) 4. Classification for model FDD-MB-3V-OW: Fire Resistance Classification: 90 Min. Damper Mounting Position: Vertical & Horizontal Shape: Rectangular Airflow and Pressure Closure Rating: 10.2 m/s and 1.0 KPa Damper Size: o Maximum Single Section (in): 36 x 48 (W x H) o Multiple Section (in): 42 x 48 (W x H) |
الإمارات العربية المتحدة | EH Price Gulf | 30524 | |
| مثبط - مثبط الحريق | Fire Damper Model FDD-MB-3V-OW |
Classification for model FDD-MB-3V-OW: Fire Resistance Classification: 90 Min Damper Mounting Position: Vertical & Horizontal Shape: Rectangular Airflow and Pressure Closure Rating: 10.2 m/s and 1.0 KPa Damper Size: Maximum Single Section (in): 36 x 48 (W x H) Multiple Section (in): 42 x 48 (W x H) |
الإمارات العربية المتحدة | EH Price Gulf | 30524 | |
| مثبط - مثبط الحريق | Fire Damper Model FDD-MB-AF-FA |
Classification for model FDD-MB-AF-FA: Fire Resistance Classification: 90 Min. Damper Mounting Position: Vertical Shape: Rectangular Airflow and Pressure Closure Rating: 10.2 m/s and 1.0 KPa Damper Size: o Maximum Single Section (in): 36 x 48 (W x H) o Multiple Section (in): N/A |
الإمارات العربية المتحدة | EH Price Gulf | 30524 | |
| مثبط - مثبط الحريق | Fire Damper Model FDD-MB-AF-OW |
Classification for model FDD-MB-AF-OW Fire Resistance Classification: 90 Min Damper Mounting Position: Vertical & Horizontal Shape: Rectangular Airflow and Pressure Closure Rating: 10.2 m/s and 1.0 KPa Damper Size: o Maximum Single Section (in): 36 x 48 (W x H) o Multiple Section (in): 42 x 48 (W x H |
الإمارات العربية المتحدة | EH Price Gulf | 30524 | |
| مثبط - دمج (دخان / حريق) مثبط | MOTORISED FIRE AND SMOKE DAMPERS K-MSFD-20 |
COMBINATION FIRE AND SMOKE DAMPERS(FIRE LEAKAGE-RATED DAMPERS) Model: K-MSFD-20 Mounting Position: Vertical Fire Resistance Classification: 90 Min Leakage Class : II-250 FRAME THICKNESS-1.50MM |
الإمارات العربية المتحدة | EH Price Gulf | 30524 | |
| مثبط - دمج (دخان / حريق) مثبط | Combination Fire And Smoke Damper Model FSD-RD |
Classification for model FSD-RD:Fire Resistance Classification: 90 MinLeakage Classification: 1-350 Airflow and Pressure Closure Rating: 10.2 m/s and 1.0 Kpa Damper Mounting Position: Vertical & Horizontal Damper Size:o Single Section Diameter (in): 8- 24 |
الإمارات العربية المتحدة | EH Price Gulf | 30524 | |
| مثبط - دمج (دخان / حريق) مثبط | Combination Fire And Smoke Damper Model FSD-AF-211 & FSD-AF-212 & FSD-AF-231 & FSD-AF-232 &FSD-AF-OW-211 |
Classification for model FSD-AF-211: Hourly Classification: 1.5 Hrs. Leakage Classification: 1-250 Airflow and Pressure Closure Rating: 10.2 m/s and 1.0 Kpa Damper Mounting Position: Vertical Damper Size:o Single Section Width (in): 8 - 36 (min-max)o Single Section Height (in): 8 - 48 (min-max)o Multiple Section (in): 108 x 96 (W x H)Classification for model FSD-AF-211:Hourly Classification: 1.5 Hrs.Leakage Classification: 1-250Airflow and Pressure Closure Rating: 10.2 m/s and 1.0 KpaDamper Mounting Position: HorizontalDamper Size:o Single Section Width (in): 8 - 36 (min-max)o Single Section Height (in): 8- 48 (min-max)o Multiple Section (in): N/AClassification for model FSD-AF-212:Hourly Classification: 1.5 Hrs.Leakage Classification: 11-350Airflow and Pressure Closure Rating: 10.2 m/s and 1.0 KpaDamper Mounting Position: VerticalDamper Size:o Single Section Width (in): 8 - 36 (min-max)o Single Section Height (in): 8- 48 (min-max)o Multiple Section (in): 108 x 96 (W x H)Classification for model FSD-AF-212:Hourly Classification: 1.5 Hrs.Leakage Classification: 11-350Airflow and Pressure Closure Rating: 10.2 m/s and 1.0 KpaDamper Mounting Position: HorizontalDamper Size:o Single Section Width (in): 8 - 36 (min-max)o Single Section Height (in): 8- 48 (min-max)o Multiple Section (in): N/A Classification for model FSD-AF-231:Hourly Classification: 3 Hrs.Leakage Classification: 1-250Airflow and Pressure Closure Rating: 10.2 m/s and 1.0 KpaDamper Mounting Position: VerticalDamper Size:O Single Section Width (in): 8 - 36 (min-max)o Single Section Height (in): 8- 48 (min-max)o Multiple Section (in): 72 x 96 (W x H)Classification for model FSD-AF-231:Hourly Classification: 3 Hrs.Leakage Classification: 1-250Airflow and Pressure Closure Rating: 10.2 m/s and 1.0 KpaDamper Mounting Position: HorizontalDamper Size:o Single Section Width (in): 8 - 36 (min-max)o Single Section Height (in): 8- 48 (min-max)o Multiple Section (in): N/A Classification for model FSD-AF-232:Hourly Classification: 3 Hrs.Leakage Classification: 11-350Airflow and Pressure Closure Rating: 10.2 m/s and 1.0 KpaDamper Mounting Position: Vertical |
الإمارات العربية المتحدة | EH Price Gulf | 30524 | |
| مثبط - دمج (دخان / حريق) مثبط | Combination Fire And Smoke Damper Model FSD-3V-211 & FSD-3V-212 & FSD-3V-231 & FSD-3V-232 & FSD-3V-OW-211 |
COMBINATION OF FIRE AND SMOKE DAMPERS:1. Classification for model FSD-3V-211: Fire Resistance Classification: 90 Min. Leakage Classification: 1-350 Airflow and Pressure Closure Rating: 10.2 m/s and 1.0 Kpa Damper Mounting Position: VerticalDamper Size:o Single Section Width (in): 8 - 36 (min-max)o Single Section Height (in): 6- 48 (min-max)o Multiple Section (in): 108 x 96 (W x H)2.Classification for model FSD-3V-211:Fire Resistance Classification: 90 MinLeakage Classification: 1-350Airflow and Pressure Closure Rating: 10.2 m/s and 1.0 KpaDamper Mounting Position: HorizontalDamper Size:o Single Section Width (in): 8 - 36 (min-max)o Single Section Height (in): 6- 48 (min-max)o Multiple Section (in): 72 x 96 (Wx H)3.Classification for model FSD-3V-212:Fire Resistance Classification: 90 MinLeakage Classification: 11-350Airflow and Pressure Closure Rating: 10.2 m/s and 1.0 KpaDamper Mounting Position: VerticalDamper Size:o Single Section Width (in): 6 - 36 (min-max)o Single Section Height (in): 6- 48 (min-max)o Multiple Section (in): 108 x 96 (W x H)4.Classification for model FSD-3V-212:Fire Resistance Classification: 90 MinLeakage Classification: 11-350Airflow and Pressure Closure Rating: 10.2 m/s and 1.0 KpaDamper Mounting Position: HorizontalDamper Size:o Single Section Width (in): 6- 36 (min-max)o Single Section Height (in): 6- 48 (min-max)o Multiple Section (in): 72 x 96 (W x H)5.Classification for model FSD-3V-231:Fire Resistance Classification: 180MinLeakage Classification: 1-350Airflow and Pressure Closure Rating: 10.2 m/s and 1.0 KpaDamper Mounting Position: Vertical & HorizontalDamper Size:o Single Section Width (in): 6 - 36 (min-max)o Single Section Height (in): 6- 48 (min-max)o Multiple Section (in): 72 x 96 (Wx H)6.Classification for model FSD-3V-232:Fire Resistance Classification: 180 Min Leakage Classification: 11-350 Airflow and Pressure Closure Rating: 10.2 m/s and 1.0 Kpa Damper Mounting Position: Vertical & Horizontal Damper Size:o Single Section Width (in): 6 - 36 (min-max)o Single Section Height (in): 6- 48 (min-max)o Multiple Section (in): 72 x 96 (Wx H)7.Classification for model FSD-3V-OW-211:Fire Resistance Classification: 90 MinLeakage Classification: 1-350Airflow and Pressure Closure Rating: 10.2 m/s and 1.0 KpaDamper Mounting Position: Vertical & HorizontalDamper Size:o Single Section Width (in): 6 - 36 (min-max)o Single Section Height (in): 6- 48 (min-max)o Multiple Section (in): 42 x 48 (Wx H)o Multiple Section (in): 108 x 96 (W x H) |
الإمارات العربية المتحدة | EH Price Gulf | 30524 | |
| مثبط - دمج (دخان / حريق) مثبط | Combination Fire And Smoke Damper Model FSD-RD |
Classification for model FSD-RDFire Resistance Classification: 90 Min. Leakage Classification: 1-350 Airflow and Pressure Closure Rating: 10.2 m/s and 1.0 Kpa Damper Mounting Position: Vertical & Horizontal Damper Size:o Single Section Diameter (in): 8- 24 |
الإمارات العربية المتحدة | EH Price Gulf | 30524 | |
| القنوات مقاوم للحريق | DELTA-FLEX & DELTA-FLEX-AC |
1. Product Model: DELTA-FLEX. Product Category: Air Duct, Flexible Duct. Minimum Side Dimension Without Reinforcement or Diameter: 76.2 mm.? Maximum Side Dimension Without Reinforcement or Diameter: 508 mm.? Rated Air Velocity: 25 m/s.? Rated Positive Pressure: 2.5 kpa.? Rated Negative Pressure: 0.125 kpa..? Class Rating: Class 1 - having a flame-spread index of not over 25 without evidence of continued progressive combustion and a smoke-developed index of not over 50.2. Product Model: DELTA-FLEX-AC.? Product Category: Air Duct, Flexible Duct.? Minimum Side Dimension Without Reinforcement or Diameter: 76.2 mm. Maximum Side Dimension Without Reinforcement or Diameter: 508 mm.Rated Air Velocity: 25.4 m/s. Rated Positive Pressure: 0.5 kpa. Rated Negative Pressure: 0.125 kpa.Class Rating: Class 1 - having a flame-spread index of not over |
الإمارات العربية المتحدة | Delta Duct Airconditioning | 15371 | |
| القنوات مقاوم للحريق | KAD AIRCONDITIONING-1971 | FIRE RESISTING VENTILATION DUCTS WITH REFERENCE:KKFRD-Fy-60 DUCT TYPE A AND B MADE OF GI, MILD OR STAINLESS STEEL. | الإمارات العربية المتحدة | KAD AIRCONDITIONING | 3968 |