اسم المعدة الاسم التجاري رقم الموديل بلد الصنع مصنع رقم قيد الوكالة تاريخ انتهاء قيد الوكالة
مثبط - مثبط الدخان SAFE4 UL Dampers Combination Fire and Smoke DampersDampers rated 2000 fpm / 4.0 in. WC.F/S-3V-I, FSD-3V-211, F/S-3V-CR-I, F/S-3V-II,
FSD-3V-212,F/S-3V-CR-II - (1-1/2 h)F/S-3V-3-I, FSD-3V-231, F/S-3V-3-CR-I, F/S-3V-3-II, FSD-3V-232, F/S-3V-3-CR-II - (3 h)F/S-3V-OW-I,
FSD-3V-OW-21,F/S-3V-OW-II, FSD-3V-OW-212, F/S-3V-FA-I, FSD-3V-FA-211, F/S-3V-FA-II, FSD-3VFA-212, F/S-AF-II, FSD-AF-212, F/S-AF-I,
F/S-AF-II,FSD-AF-211, -212 - (1-1/2 h)F/S-AF-3-I, F/S-AF-3-II, FSD-AF-231, -232, F/S-AF-3-II, FSD-AF-232 - (3 h)F/S-AFM-PB-I,
F/S-AFM-OB-I,F/S-AFM-PB-II, F/S-AFM-OB-II - (1-1/2 h)F/S-AFM-PB-3-I, F/S-AFM-OB-3-I, F/S-AFM-PB-3-II, F/S-AFM-OB-3-II - (3
h)F/S-AF-OW-I,FSD-AF-OW-211, F/S-AF-OW-II, FSD-AF-OW-212, F/S-AF-FA-I, FSD-AF-FA-211, F/S-AF-FA-II, FSD-AF-FA-212, F/S-RD-I, FSD-RD,
F/S-RD-II, FSD-RD -(1-1/2 h)Max Size Single Section 36"x48"Max Size Multiple Section 108"x96"Mounting Vertical or HorizontalElevated
Temperature 250F or350FDampers rated 4000 fpm / 6.0 in. WC:FSD-AF-211, F/S-AF-I, FSD-AF-212, F/S-AF-II - (1-1/2 h)FSD-AF-231, F/S-AF-3-I,
FSD-AF-232,F/S-AF-3-II - (3 h)Max Size Single Section 36"x36"Mounting Vertical or HorizontalElevated Temperature 250F
الإمارات العربية المتحدة Central Ventilation System L.L.C 15302
مثبط - مثبط الدخان SAFE4 UL Dampers Smoke DampersDampers rated 2000 fpm / 4.0 in. WCS-3V-I, SSD-3V-201, S-3V-II, SSD-3V-202, S-AF-I, SSD-AF-201, S-AF-II,
SSD-AF-202,S-AFM-PB-I, S-AFM-OB-I, S-AFM-PB-II, S-AFM-OB-II, S-RD-I, SSD-RD-201, S-RD-II, SSD-RD-202, SSD-3V-FA-201, SSD-3V-FA-202,
SSD-3V-OW-201,SSD-3V-OW-202, SSD-AF-FA-201, SSD-AF-FA-202, SSD-AF-OW-201, SSD-AF-OW-202.Mounting Vertical or HorizontalElevated
Temperature 250F or350FMax Size Single Section 36"x48"Max Size Multiple Section 144"x96"Dampers rated 4000 fpm / 6.0 in. WCS-AF-I,
SSD-AF-201, S-AF-II,SSD-AF-202Mounting Vertical or HorizontalElevated Temperature 250FMax Size Single Section 36"x36"
الإمارات العربية المتحدة Central Ventilation System L.L.C 15302
مثبط - مثبط الحريق SAFE4 UL Dampers Fire Dampers Use in Static SystemsFD*, FD-SL* - (1-1/2 h, 3 h)FD-USL* (1-1/2 h, 3h)FD-OW*, FD-SL-OW* - (1-1/2 h)FD-110-3V,
FD-110-3V-OW,FD-110-3V-FA, FD-MB-3V(M), FD-MB-3V-OW(M), FD-MB-3V-FA(M) - (1-1/2 h, 3h)FD-MB-3V, FD-MB-3V-OW, FD-MB-3V-FA - (1-1/2 h,
3h)FD-160-AF,FD-160-AF-OW, FD-160-AF-FA, FD-MB-AF(M),FD-MB-AF-OW(M), FD-MB-AF-FA(M) - (1-1/2 h, 3h)FD-MB-AF, FD-MB-AF-OW, FD-MB-AF-FA -
(1-1/2 h,3h)FD-R, FD-RD, FD-A-3V - (1-1/2 h)* may also have suffixes -A, -B, -C-S/R, -C-R or -C-OVMounting Vertical or HorizontalSingle
Section Max60"x60"Multiple Section Max 120"x120"Fire Dampers Use in Dynamic SystemsDampers rated 2000 fpm / 4.0 in. WCFDD*, FDD-SL* -
(1-1/2 h,3h)FDD-OW*, FDD-SL-OW* - (1-1/2 h)FDD-110-3V, FDD-MB-3V (M), FDD-MB-3V - (1-1/2 h, 3h) FDD-110-3V-OW, FDD-MB-3V-OW (M),
FDD-MB-3V-OW -(1-1/2 h)FDD-110-3V-FA, FDD-MB-3V-FA (M), FDD-MB-3V-FA - (1-1/2 h)FDD-160-AF, FDD-MB-AF (M), FDD-MB-AF - (1-1/2 h,
3h)FDD-110-AF-OW,FDD-MB- AF-OW (M), FDD-MB- AF-OW - (1-1/2 h)FDD-110-AF-FA, FDD-MB- AF-FA (M), FDD-MB- AF-FA - (1-1/2 h)FDD-R, FDD-RD -
(1-1/2 h)* may alsohave suffixes -A, -B, -C-S/R, -C-R or -C-OVMounting Vertical or HorizontalSingle Section Max 36"x48"Multiple Section
Max 108"x96
الإمارات العربية المتحدة Central Ventilation System L.L.C 15302
مثبط - دمج (دخان / حريق) مثبط SAFE4 UL Dampers Corridor DampersF/S-3V-CR-I, F/S-3V-CR-IIMin Size 6x24Max Size 6x24 الإمارات العربية المتحدة Central Ventilation System L.L.C 15302
القنوات مقاوم للحريق SAFE4 FIRE RATED DUCT RGIL120 - (R 120/ E 120), RGIL240 - (R 240/ E 240), RMSW120- (R 120/ E 120), RMSW240 - (R 240/ E 240), RSSL120 - (R 120/ E 120), RSSL240
-(R 240/ E 240), RSSW120 - (R 120/ E 120), RSSW240 - (R 240/ E 240), CGIL120 - (R 120/ E 120), CGIL240 - (R 240/ E 240), CSSL120 - (R
120/E 120), CSSL240 - (R 240/ E 240), CSSW120 - (R 120/ E 120), CSSW240 - (R 240/ E 240), CMSW120 - (R 120/ E 120), CMSW240 - (R 240/ E
240),MSTM, OSTM, DSTM, TSTM, RSTD-I, RCDA, RCDA-S, CCDA, Type A & Type B with Stability (R) 120 / 240 min & Integrity (E) 120 /
240 minwith Type A Insulation (I) 180m & Type B Insulation (I) 60 min with Insulfrax.Thickness 0.80mm, 1.00mm,1.20mmCompliance with
BS476 -P24 & BS EN 1366-1:1999.Type A & Type B Tested at temperature of 1150 CFor pressure classification up to 4000 pa. Above
modelsshall be used as assembly system only-SAFE4 Fire Rated Smoke Extract Duct System - R/E 120min & 240min-SAFE4 Fire Rated
Kitchenextract System - R/E 120min & 240min-SAFE4 Fire Rated Ventilation Duct System - R/E 120min & 240min-SAFE4 Fire
RatedPressurization Duct System -R/E 120min & 240minMax Duct Size 8m x 6m
الإمارات العربية المتحدة Central Ventilation System L.L.C 15302
مواد مانعة لإنتشار الحريق - نظام مانع لإنتشار الحريق Unifrax FyreWrap Elite 1.5 Insulationfor Type A - 120 min Insulation Rating with 38mm thickness.for Type B - 120 min Insulation Rating with
76mmthickness.Trafalgar Fyrewrap Elite 1.5 consists of high temperature insulation made from calcia, magnesia and silica chemistry with
aservice limit exceeding 1000 degC and is fully encapsulated in an fiberglass-reinforced aluminium foil, scrim covering that
provideshandling strength as well as protection from moisture absorption Flame FyreWrap Elite 1.5 Duct InsulationCeramic fiber insulation
with orwithout facings designated FIRESTOP BLANKET or FSB DuctInsulation, formed into blanketsFlame Spread 0Smoke Developed 0, 120min
InsulationRatingNote. FyreWrap Elite 1.5 Insulation shall only be used with certified fire rated ducts having Type A & Type B
Stability andIntegrity ratings.
الولايات المتحدة الأمريكية Unifrax LLC 19532
مواد مانعة لإنتشار الحريق - نظام مانع لإنتشار الحريق Unifrax FyreWrap Elite 1.5 InsulationTrafalgar Fyrewrap Elite 1.5 consists of high temperature insulation made from calcia, magnesia and
silicachemistry with a service limit exceeding 1000 degC and is fully encapsulated in an fiberglass-reinforced aluminium foil, scrim
coveringthat provides handling strength as well as protection from moisture absorption Flame FyreWrap Elite 1.5 Duct InsulationType A 38mm
withOne Layer for 2-Hour RatingType B 76mm with Two Layers for 2-Hour RatingCeramic fiber insulation with or without facings
designatedFIRESTOP BLANKET.Insulation, formed into blanketsFlame Spread 0Smoke Developed 060min, 120min Insulation Rating, refer to the
CertificateNo. WHI17-23495701
الهند Unifrax India Private Limited 19532
القنوات مقاوم للحريق SAFE 4 Fire Rated Ductwork System Model : SAFE4 Steel Ductwork Complete System as per(CF761) Type : Horizontal Ducts , Vertical Duct , Smoke
Outlet Ducts , Kitchen Extract Ducts , Circular Including Flat Oval Ducts, Both Type A & Type B Uninsulated Duct - Integrity
120&240 min, Stability 120&240 min, Insulation 0 min Insulated Duct - Integrity 120&240 min, Stability 120&240 min,
Insulation 120&180 min for Pressure Class up to 4000pa at temperature of 1150 C BS476, P 24. Approved thicknesses 0.60mm,
0.80mm,1.00mm,1.20mm,1.50mm. Tested at temperature of 1150 C Uninsulated Duct-Integrity 120&240 min, Stability 120&240 min,
Insulation 0 min. Insulated Duct-Integrity 120&240 min, Stability 120&240 min, Insulation 120&180 min
الإمارات العربية المتحدة Central Ventilation System Co. LLC 61996
القنوات مقاوم للحريق SAFE 4 Dampers for Fire Barrier and Smoke Applications Model: Fire Dampers, Smoke Dampers, Combination Fire and Smoke Dampers, Corridor Dampers
& Rated Volume Control Dampers (EMME.R27700) Type: Horizontal & Vertical, Fire Dampers, Smoke Dampers, Combination Fire and Smoke
Dampers, Corridor Dampers & Rated Volume Control Dampers for use in Static & Dynamic Systems, Rated for 1hrs , 1-1/2 hrs & 3
hrs. Full History of Damper As per UL File Number - EMME.R27700 - Fire Dampers for Static System -Fire Dampers for Dynamic System -Smoke
Dampers -Combination Fire and Smoke Dampers -Corridor Dampers -Rated Volume Control Dampers
الإمارات العربية المتحدة Central Ventilation System Co. LLC 61996
مواد مانعة لإنتشار الحريق - نظام مانع لإنتشار الحريق Unifrax FyreWrap Elite 1.5 Insulation Trafalgar Fyrewrap Elite 1.5 consists of high temperature insulation made from calcia, magnesia and silica
chemistry with a service limit exceeding 1000 degC and is fully encapsulated in an fiberglass-reinforced aluminium foil, scrim covering
that provides handling strength as well as protection from moisture absorption Flame FyreWrap Elite 1.5 Duct Insulation Type A 38mm with
One Layer for 2-Hour Rating Type B 76mm with Two Layers for 2-Hour Rating Ceramic fiber insulation with or without facings designated
FIRESTOP BLANKET. Insulation, formed into blankets Flame Spread 0 Smoke Developed 0 60min, 120min Insulation Rating, refer to the
Certificate No. WHI17-23495701
الهند Unifrax India Private Limited 19532
مواد مانعة لإنتشار الحريق - نظام مانع لإنتشار الحريق Unifrax FyreWrap Elite 1.5 Insulation for Type A - 120 min Insulation Rating with 38mm thickness. for Type B - 120 min Insulation Rating with 76mm
thickness. Trafalgar Fyrewrap Elite 1.5 consists of high temperature insulation made from calcia, magnesia and silica chemistry with a
service limit exceeding 1000 degC and is fully encapsulated in an fiberglass-reinforced aluminium foil, scrim covering that provides
handling strength as well as protection from moisture absorption Flame FyreWrap Elite 1.5 Duct Insulation Ceramic fiber insulation with or
without facings designated FIRESTOP BLANKET or FSB Duct Insulation, formed into blankets Flame Spread 0 Smoke Developed 0 , 120min
Insulation Rating Note. FyreWrap Elite 1.5 Insulation shall only be used with certified fire rated ducts having Type A & Type B
Stability and Integrity ratings.
الولايات المتحدة الأمريكية Unifrax LLC 19532
القنوات مقاوم للحريق SAFE4 As per certificate R27700 listing.Dampers for Fire Barrier and Smoke Application الإمارات العربية المتحدة Central Ventilation System Co. LLC 61996
القنوات مقاوم للحريق SAFE4 SAFE4 AS MENTIONED IN CF761, P4.Fire Rated Ductwork System الإمارات العربية المتحدة Central Ventilation System Co. LLC 61996